ECS data bus cables are designed to meet, or exceed, burn requirements as set forth in Federal Aviation Regulations 14 CFR Part 25.869(a)(4) Amdt 25-113, Appendix F Part I(a)(3). They are manufactured with materials which, when subjected to flames or high temperatures, will not outgas deadly hydrogen chloride produced by conventional PVC cables.
规格:
Weight:
3.0 lb/100 ft nominal
Outer diameter:
0.234 in. nominal
Bend radius:
1.2 in. nominal
Impedance:
100Ω nominal
Capacitance:
12.4 pF/ft maximum
Velocity of propagation:
78% nominal
Skew:
12.8 ns/100ft BUS
Attenuation:
10 MHz 2.1 dB/100 ft nominal
Conductors:
4 (2 Twisted Pairs: Conductors: 24 AWG tin plated copper Insulation: High temperature flouropolymer)
Color Code:
Pair 1- White/Blue, Blue/White
Pair 2 - White/Orange, Orange/White
Shield 1:
Aluminum/Mylar foil
Shield 2:
38 AWG tin plated copper braid
Jacket:
White high temperature flouropolymer (laser markable)
特征:
4 conductor
2 twisted pair
White/blue, Blue/white
White/orange, Orange/white
Dual shielding
Hight temp outer insulation