TheDT600is a combination ARINC 429/629 databus analyzer with independent ports for each bus which operate independently of each other. Each bus provides basic receive and transmit function, a general record mode and a robust breakpoint mode. The RS-232 port is used to download real time data and upload label and word definitions, and the DAC port is used to provide a trigger pulse or drive recorders or instruments. An optional GPIB port can be added to provide remote control access and PC software is available which allows the user to define their own date definition table(s).
规格:
Weight:
24 lb (10.9 kg)
Dimensions:
5.7 x 14.25 x 12 in (14.5 x 36.2 x 30.5 cm)
特征:
This DT-600 Databus Analyzer(EDMO#DT-600):
Provides the William Protocol
Single channel ARINC 629
Features:
Two ARINC TX/RX ports and two ARINC629 transceiver ports
Operates six to eight hours on the internal battery or power from external 28 VDC or 105 VAC – 250 VAC
Easy menu-driven setup allows intuitive control of the unit
Multi-window display of data in engineering (B777 default for 629), hex, binary, user defined, and graphical formats
Powerful record and fault analyzer modes
Williamsburg Protocol software extension available for ARINC 429 file transfer functions
RS-232C and DAC interface ports standard; GPIB optional
Software available for RS-232 port to download and upload and word definitions