The CAT III 1000V / CAT IV 600V safety rated Fluke ScopeMeter® 190-102 combines an unprecedented level of performance, ruggedness, and portability with 100MHz bandwidth and real-time sampling rates up to 1.25 GS/s and 200 ps resolution to capture noise and other disturbances. This model feature deep memory up to 10,000 samples per channel; so you can examine very small parts of the waveform in detail, and it is IP-51 rated to withstand dust, drips, humidity, and wide temperature variations. Fluke ScopeMeter® test tools are hand-held battery operated, designed to meet the demands of field service professionals.
规格:
Weight:
4.85 lb
Dimensions:
10.62 x 7.48 x 2.75 in.
Bandwidth:
100 MHz
Number of channels:
100 MHz: 2 channels
Real-time sample rate:
1.25 GS/s
Inputs:
2 scope plus DMM input
Independently floating isolated inputs:
Up to 1000 V CAT III/600 V CAT IV between inputs, references and ground
Timebase range:
5 ns - 2 min/div
Input sensitivity:
2 mV-100 V/div
Trigger types:
Connect-and-View™, Free Run, Single Shot, Edge, Delay, Dual Slope, Video, Video Line, Selectable pulse width, N-Cycle
Trigger source:
Any scope input channel, or external via DMM input
Glitch capture:
8 ns
Scope measurements:
Cursor: 7
Automatic: 30
Maximum record length:
ScopeRecord mode: 30,000 pts
Scope mode: 10,000 pts per input
Persistence:
Digital persistence giving analog oscilloscope-like waveform decay
Waveform compare:
Waveform reference with automatic Pass/Fail testing
DMM Specification
Meter inputs (also used as External Trigger Input for the Oscilloscope Mode):
4 mm banana inputs, fully isolated from scope inputs and from scope ground
Maximum resolution:
5000 counts
Measurements:
VDC, VAC rms, VAC + DC rms, Resistance, Continuity, Diode Test, Current (through clamp or shunt), Temperature °C or °F (using optional converter)
Memory:
2 Channel
Screen + Setup: 30
Recording: 10
Display:
153 mm full color LCD with fast update rate
Environmental Specifications
Operating temperature:
0 °C to 40 °C Including Batteries
0 °C to 50 °C Excluding Batteries
Storage temperature:
-20 °C to +60 °C
Operating altitude:
Up to 2,000 m (6666 ft) for CAT IV 600 V, CAT III 1000 V
Up to 3,000 m (10,000 ft) for CAT III 600 V, CAT II 1000 V
Safety Specifications
Electrical safety:
1,000V CAT III/600V CAT IV (EN61010-1)
特征:
Includes:
VPS410 Voltage Probe Sets (one red, one blue)
TL175 TwistGuard? safety designed Test Lead Set (red and black)
BC190 Battery Charger/mains Adapter
BP290 2400 mAh Li-ion Battery
Handstrap (affixed to instrument)
Hangstrap
Multi-Language User Manuals on CD-Rom
FlukeView ScopeMeter? demo package (restricted functionality)
USB Interface Cable
Features:
Two electrically isolated inputs
CAT III 1000V / CAT IV 600V safety rated
100 MHz bandwidth model
1.25 GS/s
Deep memory: 10,000 samples per channel waveform capture so you can zoom in on the details
Dedicated 5000 Count digital multimeter
Connect-and-View continuous auto-trigger, single shot, pulse width, and video triggering
ScopeRecord roll mode, capture waveform sample data for up to 48 hours
TrendPlot, trend measurement readings for up to 22 days
Advanced automatic measurements, power (Vpwm, VA, W, PF) and time (mAs, V/s, w/s)
IP-51 rated for dust and drip proof to withstand harsh environments
Isolated USB ports for memory devic