Home | Favorites 中文版  
Email: Password:
2597 companies with 2074412 item
Products Information
Name: ATC/DME/MODE S Test Set
Model: TB-2100
Supplier:Tel-Instrument Electronics Corp.
Contact Info
East Wonder Internation,Inc.17 Lillian Road
Lexington,MA 02420 USA
Tel:781-856-2376
Fax:781-652-8868
E-mail:jxu@eastwonderus.com
Contact: John Xu/President
Product Introduction:
• Two independent, non-coherent, RF channels for Mode S testing
• Tests the latest Mode S Capabilities
o Automatic Dependent Surveillance Broadcast (ADS-B)
o Extended Squitter
o Elementary (ES) and Enhanced Surveillance (EHS)
o Traffic Information Systems (TIS)
• Easy to Use
o Modern front-panel provides simple, intuitive, interface
o Multiple, variable rate slew knobs control pulse width, power, repetition rates, and position
o Keypad supports direct test parameter entry
o Large color, touch-pad display, which continuously presents critical measurement information and permits immediate test parameter selection
o Quick recall of standard test conditions using CAL button
• Additional Benefits
o Provides video and RF signal feeds plus scope triggers
o Can be connected to spectrum analyzers and other bench equipment
o Flash memory provides easy update/upgrade path
o Standard 2 year limited warranty; extended warranty available
Technical Parameter:
Specifications      
Signal Generator   Mode S (Continued)  
Frequency Range 952.00 to 1223.00 MHz P4 Width 0.80 or 1.60 + 0.5 μs, variable -0.50 to 1.00 μs
Frequency Accuracy 0.00% Sync Phase Reversal 2.75 + 0.05 μs, variable -0.50 to +0.50 μs
Frequency vs. Level Flatness <1.0 dB (SPR relative to P2)  
Signal Level Range 0 to -100 dBm into 50 Ω, 1 dB resolution P5 Position 0.40 + 0.05 μs before SPR, variable -1.00 to
Signal Level Accuracy 0 to -50 dBm + 0.75 dB (Relative to SPR) +1.00 μs
  -51 to -79 dBm + 1.0 dB P6 Position 1.25 + 0.50 μs before SPR, variable -0.40 to
  -80 to -89 dBm + 1.1 dB (Relative to SPR) +3.00 μs
  -90 to -100 dBm + 1.2 dB Interference Pulse Position -1.40 to +45 + .05 μs , variable in 50 ns steps
On/Off Ratio > 60 dB (Relative to P1)  
Suppressor Pulse Amplitude Variable from 9 to 28 V Interference Pulse Width 0.30 to 3.00 μs + 1%, variable in 50 ns steps
Suppressor Pulse Width 35 + 5 μs Interference Pulse/P5 Level -15 to +3 dB + 0.25 dB, variable in 1 dB steps
    (relative to P1)  
UUT Measurements   DME Mode  
Frequency 1020 to 1155 MHz; + 20 kHz for ATC; + 50 kHz Mode VOR Pair, TACAN Channel, MHz
  for DME    
Power 0 to 4000 W pk; + 0.7 dB 1 to 99 W; + 0.5 dB Pulse Characteristics  
  100 to 4000 W    
    P1 Rise time 2.0 +/- 0.5 us
Transponder Modes Mode ATCRBS and Mode S P1 Fall time P1 Width 2.5 +/- 0.5 us 3.5 +/- 0.2 us
    P2 Rise time 2.0 +/- 0.5 us
Pulse Characteristics   P2 Fall time 2.5 +/- 0.5 us
    P2 Width 3.5 +/- 0.2 us
Rise time (P1) 75 + 25 ns P2 Position X Mode – 12.0 + 0.2 μs, variable -6.00 to +6.00
Fall time (P1) 150 + 50 ns (Relative to P1) in 0.1 μs steps
      Y Mode – 30.0 + 0.2 μs, variable
ATCRBS Mode A/C   Echo Position (30 nmi) -6.00 to +6.00 in 0.1 μs steps 426.65 +/-.25 us
Pulse Width (P1/P2/P3) 0.80 + .05 μs, variable -0.3 to 1.4 μs in 50 ns Scope Sync Width 0.8 to 1.2 μs
  steps PRF 1 to 5000 Hz
P2 Position (Relative to P1) 2.00 + .05 μs, variable + 1.00 μs in 50 ns steps 15/135 Hz Modulation  
Mode C P3 Position (Relative 21.00 + .05 μs, variable + 1.00 μs in 50 ns Percent Modulation 30 to 50 %
to P1) steps 15 Hz Modulation 15 +/-1 Hz
Interference Pulse Width 0.30 to 3.00 μs + 1%, variable in 50 ns steps 135 Hz Modulation 135 +/-2 Hz
Interference Pulse Position -5 to +45 + .05 μs , variable in 50 ns steps Reply Efficiency 0 to 100% + 5%, selectable in 10% increments
(Relative to P1)   Range 0 to 998 nmi. + 0.02 nmi. Plus + 0.005% of
Interference Pulse Selectable for coherent or non-coherent   selected range
RF source   Velocity 0 to 9990 kts. + 0.05%, selectable in 0.01 nmi.
Interference Pulse/SLS Level -15 to +3 dB + 0.25 dB, variable in 1 dB steps   Increments
(relative to P1)   Echo Level -12 to +3 dB + 0.25 dB, variable in 1 dB steps
PRF 0.1 to 2500 Hz Front Panel BNC Connectors Spectrum Analyzer (Top and Main)
Scope Sync Width 0.8 to 1.2 μs   UUT Video (Top and Main)
Scope Sync Position 0 to 175 μs in 1 μs steps   Test Set Video (Top and Main)
(Relative to P1)     Scope Sync
A/C Interlace Mode 1.00 + 0.20 ms   Suppressor Pulse (ATC and DME)
Interrogation Spacing   Rear Panel BNC Connectors RS-232 (Calibration and Software Update)
Double Mode Interrogation     DPSK Modulation Input
Interrogation Spacing 3 to 500 μs   External SLS
      Video Input for Mode S Interrogation
Mode S     Low Power Input
      External Trigger
Pulse Width (P1/P2/P3) 0.80 + .05 μs, variable -0.3 to 1.4 μs in 50 ns    
  steps General  
P2 Position (Relative to P1) 2.00 + .05 μs, variable + 1.00 μs in 50 ns steps    
Mode A P3 Position (Relative to P1) Mode C P3 Position (Relative to P1) P4 Position (Relative to P3) 8.00 + .05 μs, variable + 1.00 μs in 50 ns steps 21.00 + .05 μs, variable + 1.00 μs in 50 ns steps 2.00 + 0.5 μs, variable + 1.00 μs in 50 ns steps Power Dimensions Weight Temperature 100 to 120 VAC, 60 Hz; 220 to 240 VAC, 50 Hz 14.5 in. W x 11.0 in. H x 14.25 in. D 368 mm W x 279 mm H x 362 mm D 28 lbs. (12.7 kg.) 5 to 40°C
Related Document:
DownLoad
Contact Us  Privacy Policy  Advertise With Us  Sitemap
沪ICP备08017026号 Copyright 1999-2011 Airparts.cn- All rights reserved  Email: info@airparts.cn